These Electron Current Spectra in the Jovian Magnetosphere are from the Plasma Spectrometer (PLS) Instrument on Voyager 1 during March 1979 Flyby of Jupiter. The Instrument has four Faraday Cups A, B, C, and D, the Electron Data come only from Faraday Cup D. The Data are specified in Terms of Current per Faraday Cup in femto-amperes (10^-15 A equals 1 fA) versus Channel Number and Energy (eV). This Data Set is for the PLS E2 Mode covering Electron Energies from 10 eV to 5950 eV in 16 logarithmic Energy Channels. The PLS Instrument samples only one Mode of Electron (E1, E2) or Ion (L, M) Spectra in each Time Interval, so the E2 Data are not continuous but consecutive with the other Modes in Time. Reference: Bridge, H.S., Belcher, J.W., Butler, R.J., Lazarus, A.J., Mavretic, A.M., Sullivan, J.D., Siscoe, G.L., and V.M. Vasyliunas, The Plasma Experiment on the 1977 Voyager Mission, Space Sci. Rev., 21, 259-287, 1977.
Version:2.3.0
These Electron Current Spectra in the Jovian Magnetosphere are from the Plasma Spectrometer (PLS) Instrument on Voyager 1 during March 1979 Flyby of Jupiter. The Instrument has four Faraday Cups A, B, C, and D, the Electron Data come only from Faraday Cup D. The Data are specified in Terms of Current per Faraday Cup in femto-amperes (10^-15 A equals 1 fA) versus Channel Number and Energy (eV). This Data Set is for the PLS E2 Mode covering Electron Energies from 10 eV to 5950 eV in 16 logarithmic Energy Channels. The PLS Instrument samples only one Mode of Electron (E1, E2) or Ion (L, M) Spectra in each Time Interval, so the E2 Data are not continuous but consecutive with the other Modes in Time. Reference: Bridge, H.S., Belcher, J.W., Butler, R.J., Lazarus, A.J., Mavretic, A.M., Sullivan, J.D., Siscoe, G.L., and V.M. Vasyliunas, The Plasma Experiment on the 1977 Voyager Mission, Space Sci. Rev., 21, 259-287, 1977.
| Role | Person | |
|---|---|---|
| 1. | PrincipalInvestigator | spase://SMWG/Person/John.D.Richardson |
| 2. | MetadataContact | spase://SMWG/Person/Robert.M.Candey |
| 3. | MetadataContact | spase://SMWG/Person/Lee.Frost.Bargatze |
Voyager Plasma Science Experiment Web Page at MIT
Access to Data in CDF Format via ftp from SPDF
Access to Data in CDF Format via http from SPDF
Access to ASCII, CDF, and Plots via NASA/GSFC CDAWeb
CDF Epoch Time for the Event, Format: DD-MON-YYYY HH:MM:SS.SSS
Integer Year, Four Digit
Integer Month of Year
Integer Day of the Month
Integer Hour of the Day
Minute of the Hour
Second of the Minute
Millisecond of the Second
Fractional Year
Integer Day of the Year
E2 Mode Electron Current from Faraday Cup D versus Electron Energy from 10 eV to 5950 eV
Energy Channel Number for Electrons in E2 Mode, High-Energy Resolution