The GOES 13 High Energy Proton and Alpha Detector (HEPAD) provides flux measurements of high energy proton and alpha particles. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data files contain mainly information on the number of particles per average and count rates for the HEPAD sensor. Data files contain long descriptive header.
Version:2.3.1
The GOES 13 High Energy Proton and Alpha Detector (HEPAD) provides flux measurements of high energy proton and alpha particles. For more information, please see Onsager et al. 1996, Operational uses of the GOES energetic particle detectors, in GOES 8 and Beyond, Proc. SPIE, Vol. 2812, edited by E. R. Washwell, pp. 281-290, Bellingham, WA. These data files contain mainly information on the number of particles per average and count rates for the HEPAD sensor. Data files contain long descriptive header.
| Role | Person | |
|---|---|---|
| 1. | PrincipalInvestigator | spase://SMWG/Person/Terry.Onsager |
| 2. | MetadataContact | spase://SMWG/Person/James.M.Weygand |
Information about the magnetometers onboard GOES 14
Direct link to the GOES 14 High Energy Proton and Alpha Detector (HEPAD) data in CSV format as well as the energetic particle data from other GOES spacecraft. The data are sorted by year, month, spacecraft, and file type. The file names indicates the data type, spacecraft number, year, month, and resolution. For example, g14_hepad_s15_1m_20100501_20100531.csv, indicates GOES 14 magnetometer data at 1 min time resolution from 2010-05-01 to 2010-05-31.
Time format in data files is year-month-day hour:minute:seconds
Quality flag non-zero value indicates data quality issue
Data points per average
Counts/s from all particles that deposit >110 keV in the D1 silicon slab
Quality flag non-zero value indicates data quality issue
Data points per average
Counts/s from all particles that deposit >110 keV in the D2 silicon slab
Quality flag non-zero value indicates data quality issue
Data points per average
Counts/s from all particles that create >13.5 keV photoelectrons in the photomultiplier tube
Quality flag non-zero value indicates data quality issue
Data points per average
Counts/s from all particles that create >69 keV photoelectrons in the photomultiplier tube
Quality flag non-zero value indicates data quality issue
Data points per average
Counts/s from all particles that deposit >110 keV in both the D1 and D2 silicon slabs