SPASE.info

AMPTE/IRM Plasma Instrument

ResourceID
spase://SMWG/Instrument/AMPTE-IRM/Plasma

Description

The IRM plasma instrument (G. Paschmann, PI) consists of two symmetrical quadrispherical electrostatic analyzers, one for ions and one for electrons, which measure the complete 3-D velocity distribution function in one spacecraft revolution (4s). The energy range covered is 15eV/q to 30 keV/q for electrons and 20 eV/q to 40 keV/q for ions. The angular resolution is 22.5°. Microcomputers within the experiment compute the moments of the distribution functions in real time. An additional retarding potential analyzer measured the flux of electrons between approximately 0 and 25 eV.

For more details, see Paschmann, G., et al., The Plasma Instrument for AMPTE IRM, IEEE Trans. Geosci. Remote Sens., GE-23, 262, 1985.

View XML | View JSON

Details

Version:2.2.9

Instrument

ResourceID
spase://SMWG/Instrument/AMPTE-IRM/Plasma
ResourceHeader
ResourceName
AMPTE/IRM Plasma Instrument
AlternateName
AMPTE/IRM 3-D Plasma Analyser
AlternateName
1984-088B-03
ReleaseDate
2019-05-05 12:34:56Z
Description

The IRM plasma instrument (G. Paschmann, PI) consists of two symmetrical quadrispherical electrostatic analyzers, one for ions and one for electrons, which measure the complete 3-D velocity distribution function in one spacecraft revolution (4s). The energy range covered is 15eV/q to 30 keV/q for electrons and 20 eV/q to 40 keV/q for ions. The angular resolution is 22.5°. Microcomputers within the experiment compute the moments of the distribution functions in real time. An additional retarding potential analyzer measured the flux of electrons between approximately 0 and 25 eV.

For more details, see Paschmann, G., et al., The Plasma Instrument for AMPTE IRM, IEEE Trans. Geosci. Remote Sens., GE-23, 262, 1985.

Acknowledgement
User will acknowledge the AMPTE/IRM plasma instrument team in any publication resulting from the use of these data.
Contacts
RolePerson
1.PrincipalInvestigatorspase://SMWG/Person/Goetz.Paschmann
InformationURL
Name
AMPTE/IRM page at University of New Hampshire
URL
http://www-ssg.sr.unh.edu/index.html?tof/Missions/Ampte-irm/plasma/plasmamain.html
Description

Information on the AMPTE/IRM plasma instrument

InformationURL
Name
NSSDC Master Catalog
URL
https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=1984-088B-03
Description

NSSDC information about the AMPTE/IRM plasma instrument

InformationURL
Name
IEEE Transaction on Geoscience and Remote Sensing Article
URL
https://ieeexplore.ieee.org/document/4072289/
Description

Detailed information about the AMPTE IRM Plasma Instrument.

PriorIDs
spase://SMWG/Instrument/AMPTE_IRM/Plasma
InstrumentType
QuadrisphericalAnalyser
InvestigationName
IRM Plasma Instrument
ObservatoryID
spase://SMWG/Observatory/AMPTE-IRM